In-service inspection & testing of electrical equipment.

Written against the published specification.

See all-access plans
Pass mark 20/30 45 minutes C&G 2377 How many can I get wrong?
About this practice. Revision Robin is built and maintained by Bloor Engineering Ltd, a UK-registered company. Our PAT Testing (2377) Prep questions are written and reviewed in-house to match the current syllabus, each with a plain-English worked explanation. They are original practice material, not the official exam questions and not affiliated with or endorsed by C&G 2377. Always confirm current test rules, fees and content with the official provider. See our Terms and Privacy.
Don't cram it, drill it. Ten questions a topic beats an hour re-reading.
Free practice questions
Try 3 real PAT Testing (2377) Prep questions
Have a go, then reveal the worked explanation. A taster from a bank of 211 original questions. Unlock for unlimited drills and full timed mocks.
Q1. Which piece of UK legislation places the core legal duty on employers to ensure electrical equipment is maintained to prevent danger?
  • A.  The Electricity at Work Regulations 1989
  • B.  The Portable Appliance Testing Act 1990
  • C.  The Consumer Protection Act 1987
  • D.  The Electricity Safety, Quality and Continuity Regulations 2002
Show answer & explanation
✓ Answer: A. The Electricity at Work Regulations 1989
The Electricity at Work Regulations 1989 (EAWR), specifically Regulation 4(2), require that electrical systems be maintained so as to prevent danger. There is no 'Portable Appliance Testing Act' - PAT is simply an industry term for one method of demonstrating compliance. The 2002 Regulations govern electricity distribution networks, not workplace appliances.
Q2. Which statement best describes the protection principle of Class III equipment?
  • A.  Protection relies on limiting the supply voltage rather than insulation or earthing alone
  • B.  Protection relies on a double-pole switch disconnecting both conductors
  • C.  Protection relies entirely on the earth fault loop impedance
  • D.  Protection relies on residual current detection at the socket
Show answer & explanation
✓ Answer: A. Protection relies on limiting the supply voltage rather than insulation or earthing alone
Because Class III equipment is fed from a SELV source, the voltage itself is kept low enough that even direct contact with live parts is unlikely to cause a dangerous shock, removing the reliance on insulation class or earthing as the primary safeguard.
Q3. For a Class II (double-insulated) desk lamp used in a low-risk office, what does HSE-aligned guidance typically suggest regarding formal testing frequency compared to a Class I appliance in the same environment?
  • A.  Class II items generally need less frequent, or in some cases no, earth continuity related testing, though visual checks still apply
  • B.  Class II items always require monthly testing regardless of environment
  • C.  Class II items require the exact same frequency as Class I items with no distinction
  • D.  Class II items are exempt from all future inspection requirements
Show answer & explanation
✓ Answer: A. Class II items generally need less frequent, or in some cases no, earth continuity related testing, though visual checks still apply
Because Class II equipment relies on double insulation rather than an earth path, certain earth continuity tests are not applicable, and testing needs are generally lighter, though visual inspection remains important. This does not mean Class II items are exempt from all future checks.
Exam mode
Full mock exam
30 random questions, real timing, marked against the official pass mark. Different every time.
The first 8 of 30 questions are free, with your score on them. Finishing the paper, your result against the pass mark and every answer explained come with the paid version.
Practice material only. This is revision practice, not official training, assessment or certification, and not a substitute for the required course or supervised experience. Always confirm the current requirements with the official awarding body or test provider before relying on it.
Try it free
Topic drills
Ten quick questions on one topic, marked instantly with explanations.
1 free drill left.
Legal requirements & responsibilities · 36
Classes of equipment & construction · 35
Frequency of inspection · 35
User checks & formal visual inspection · 33
Combined inspection & testing · 36
Records & remedial action · 36

The real PAT Testing (2377) Prep: format

How many questions are in the PAT Testing (2377) Prep?

The real PAT Testing (2377) Prep has 50 questions and lasts 105 minutes. Our mock uses 30 questions in 45 minutes.

What is the PAT Testing (2377) Prep pass mark?

Real exam pass mark: 80% (40 out of 50 questions). Our mock marks you at 20 out of 30, the threshold we mark against.

What it costs, and what a resit costs

How much does the PAT Testing (2377) Prep cost?

Resit fee: £98 +VAT (exam only resit)

How hard is it

How hard is the PAT Testing (2377) Prep?

Difficulty: Moderate to high, especially for those without prior electrical knowledge.

Why people fail it

Why do people fail the PAT Testing (2377) Prep?

Figures for the real exam from vertexaisearch.cloud.google.com, checked October 2026. Fees and rules change, so confirm with the test provider before you book.
PAT Testing (2377) Prep: common questions
Frequently asked
How long do you get?
The test is timed at 45 minutes. Our full mock runs on the same clock so you can practise your pacing.
Are these the real exam questions?
No. Our questions are original and written to match the current syllabus, so they give realistic practice without copying the official paper. Every answer comes with a plain-English explanation. Always confirm current rules and content with C&G 2377.