Inspection & Testing (2391) Prep

C&G 2391 initial verification & periodic inspection.

Pass mark 24/35 60 minutes C&G 2391 How many can I get wrong?
Start with a free topic drill, see where you stand, then unlock the full mock.
Free practice questions
Try 3 real Inspection & Testing (2391) Prep questions
Have a go, then reveal the worked explanation. A taster from a bank of 237 original questions — unlock for unlimited drills and full timed mocks.
Q1. Which piece of legislation is the primary statutory instrument requiring electrical systems to be constructed and maintained so as to prevent danger, so far as is reasonably practicable?
  • A.  The Electricity at Work Regulations 1989
  • B.  BS 7671 (IET Wiring Regulations)
  • C.  The IET Guidance Note 3
  • D.  The On-Site Guide
Show answer & explanation
✓ Answer: A. The Electricity at Work Regulations 1989
The Electricity at Work Regulations 1989 (EAWR) are made under the Health and Safety at Work etc Act 1974 and are statutory law. BS 7671 and its associated IET guidance are non-statutory documents that provide a recognised means of complying with the statutory duties.
Q2. A test engineer proves a voltage indicator is working correctly before and after use on a proving unit or known live source. What is the primary purpose of this step?
  • A.  To calibrate the instrument to the exact supply voltage
  • B.  To confirm the indicator itself has not failed and would reliably show the presence of voltage
  • C.  To satisfy a manufacturer's warranty condition only
  • D.  To record the ambient temperature for the test certificate
Show answer & explanation
✓ Answer: B. To confirm the indicator itself has not failed and would reliably show the presence of voltage
Proving before and after use confirms the voltage indicator is functioning correctly, so a genuine 'dead' reading during isolation can be trusted rather than being caused by a faulty instrument. This is a core part of the HSE-recommended safe isolation procedure (GS38).
Q3. A periodic inspection reveals that the installation was wired to the 15th Edition of the Wiring Regulations and does not fully comply with the current 18th Edition. Is this alone grounds for a C2 code?
  • A.  Yes, any non-compliance with the current edition is always C2
  • B.  No, non-compliance with the current edition alone is not a reason for a code unless it presents a danger
  • C.  Yes, but only if the installation is domestic
  • D.  No, it should always be recorded as C3 regardless of risk
Show answer & explanation
✓ Answer: B. No, non-compliance with the current edition alone is not a reason for a code unless it presents a danger
BS 7671 and GN3 make clear that an installation is not required to be upgraded to comply with every subsequent edition; non-compliance with the current edition is not, by itself, a reason for a C1, C2 or C3 code unless it gives rise to a genuine element of danger. The inspector must assess actual risk, not just edition compliance.
Start here
Ten questions to see where you stand
Two minutes, no timer, marked the moment you finish with every answer explained. Then you'll know which topics need the work before you sit a full mock.
Exam mode
Full mock exam
35 random questions, real timing, marked against the official pass mark. Different every time.
Create a free account for a full mock
No card needed. A free account unlocks a full timed mock and 3 drills on every exam.
Practice material only. This is revision practice, not official training, assessment or certification, and not a substitute for the required course or supervised experience. Always confirm the current requirements with the official awarding body or test provider before relying on it.
Try it free
Topic drills
Ten quick questions on one topic, marked instantly with explanations.
1 free drill left — then a free account unlocks 3 + a full mock.
Statutory & non-statutory requirements · 34
Initial verification sequence · 36
Periodic inspection & EICR coding · 58
Continuity & insulation resistance testing · 36
Polarity, Zs & RCD testing · 35
Documentation & certification · 38
Inspection & Testing (2391) Prep — common questions
Frequently asked
How many questions are in the Inspection & Testing (2391) Prep?
The exam has 35 questions. Every Revision Robin mock uses the same 35-question format so your practice matches the real thing.
What is the pass mark for the Inspection & Testing (2391) Prep?
You need 24 out of 35 correct to pass, which is about 69%. Our mocks mark you against this exact threshold.
How long do you get?
The test is timed at 60 minutes. Our full mock runs on the same clock so you can practise your pacing.
Are these the real exam questions?
No. Our questions are original and written to match the current syllabus, so they give realistic practice without copying the official paper. Every answer comes with a plain-English explanation. Always confirm current rules and content with C&G 2391.